Why Choose Lugao Disconnector Switch
- Over twenty years of experience in manufacturing high-voltage electrical equipment.
- The production workshop covers an area of over 10,000 square meters and is equipped with advanced production machinery.
- Hundreds of experienced employees with years of deep expertise in the electrical industry.
- Successfully exported to over 50 countries worldwide and highly acclaimed.
- We have been awarded with ISO9001 certificate and our products are certificated by CE, IEC and got relative test reports.
- Providing OEM and ODM customization services.
Professional HV Disconnector Switch Factory
With over 20 years of specialized experience in manufacturing hv&mv switchgear components, Lugao has exported indoor and outdoor disconnectors to power transmission networks and OEM switchgear manufacturers in more than 50 countries.
The function of a Disconnector Switch in a power system is to offer a well established point of separation in the circuit following circuit interruption. Lugao customizes various solutions based on the voltage level, magnitude of current, type of mounting and operating mechanism, and system specifications so that customers can isolate the required portion of equipment without taking down the entire system.
For a Disconnector Switch version adapted to your power system and project requirements, consult Lugao.
Customized Disconnector Switches for Your Project
Lugao Power manufactures a wide range of specialized disconnect switches, from indoor power distribution switchgear (12kV–40.5kV) to large outdoor power transmission substations (110kV–252kV).


Why You Need Lugao HV Disconnector Switch
The disconnector switches of the Lugao are designed to meet the needs of the real power distribution systems in all their practical aspects, including isolation type, operating mechanism and installation and maintenance requirements.

The disconnector is tightly interlocked with the circuit breaker and the earting switch, so there is no possibility of hazardous mis-operation under load, which guarantees the safety of equipment and people.

Designed specifically to interface with switchgear and other substation equipment, it minimizes challenges associated with mechanical and electrical interfaces during installation.

The disconnect switch has a good resistance to rust and oxidation, so it can be used for a long time in the bad weather.

The disconnector switch can handle huge dynamic and thermal loads during a system fault, has a good short-time withstand current capability.
Clearly Visible Air Gaps Ensure Safety
Once the disconnector is opened it provides a plainly visible physical open gap in the circuit, so maintenance staff have an unequivocal safety confirmation. It also isolates equipment that has been de-energized from live high voltage busbars, which guarantees that it is impossible to be accidentally back-fed and shocked. A visible gap is a necessary safety condition for grid maintenance, overhaul and periodic system inspection


Isolate Just the Portion That Needs to Be Serviced
Maintenance of the power system does not necessarily require the entire facility to be shut down. The right Disconnector Switch configuration makes it possible to isolate a specified portion of the network from the live system after an interruption of the current it provides to the operators with more flexibility with the maintenance limits. This can help minimize the area impacted during maintenance and leave other portions of the power grid running, when allowed by system design.
HV Disconnector Switch Technical Resources
Get access to our comprehensive product catalog to learn about complete technical specifications, design, and configuration options.
Download our certified international certificates and type test reports to inspect our factory.
Watch our factory online and explore the manufacturing process of electrical equipment.
Your Trusted HV Disconnector Switch Manufacturer


Dimensional inaccuracies, bent three-phase blades and stiff linkages are found during installation on project site leading to severe delays in commissioning and potential mechanical failure. To remove the frustrations of field fitting every custom disconnector switch is fully synchronised mechanically and contact resistance is checked through on our factory test rigs at Lugao Power. This strict pre-alignment procedure will ensure that your isolator switch will run flawlessly and fit seamlessly within your switchgear panels or substation structures without any need for manual adjustment.
Applications of Disconnector Switch

Disconnector switches serve as a physical isolation barrier between busbars and lines during maintenance, possessing dynamic and thermal stability resistance and a large-distance air-insulated break.

Outdoor disconnect switches feature an exceptionally long mechanical operating life, meeting the requirements of wind power plants for frequent switching operations.

The outdoor pole-mounted disconnector is installed on the top of the pole, used to isolate the overhead line section or related equipment.

Industrial plants use disconnector switches to isolate transformers, feeders, motors, and power distribution circuits that require maintenance.

Disconnector switches are used in mv and hv collection systems in renewable energy systems to isolate feeders, transformers, and grid-connected equipment during maintenance or inspection.

The Disconnector switch helps to isolate different sections of the power supply system during maintenance, equipment replacement, and planned switching operations.
- GW4 Technical Specifications
- GW4-40.5 2 groundings
- GW4-126 2 groundings
| Rated voltage | highest voltage | Rated current | Interrupting current (peak value) | Thermal stability current (effective value) | One-minute power frequency withstand voltage (effective value) | Lightning impulse withstand voltage (peak value) | Closing and opening time | Static pulling force of connection terminal (rated value) | Current-carrying capacity of opening and closing contacts | Coulomb’s distance | Monopolar weight | Note | ||||
| To the ground | Fracture surface | To the ground | Fracture surface | |||||||||||||
| KV | KV | A | KA | KA-S | KV | KV | S | N | A | MM | Kg | |||||
| Ordinary | Anti-fouling | |||||||||||||||
| 35(40.5) | 40.5 | 630 | 50 | 20-4 | 95 | 118 | 185 | 215 | 500 | 625 | 875 | 120 | ||||
| 1000 | 80 | 31.5-4 | 145 | |||||||||||||
| 1600 | 100 | 40-2 | 1225 | 170 | ||||||||||||
| 2000 | ||||||||||||||||
| 66(72.5) | 72.5 | 630 | 50 | 20-4 | 140 | 160 | 325 | 375 | 500 | 1100 | 1600 | 180 | ||||
| 1250 | 80 | 31.5-4 | 200 | |||||||||||||
| 1600 2000 | 100 | 40-2 | 1813 | 225 | ||||||||||||
| 2205 | 230 | |||||||||||||||
| 2500 | 125 | 50-2 | ||||||||||||||
| 3150 | 125 | 50-3 | 240 | |||||||||||||
| 110(126) | 126 | 630 | 50 | 20-4 | 230(185) | 265(450) | 550(450) | 630(520) | 750 | 1870 | 2750 | 200 | It can be used at an altitude of 2500 meters in accordance with the international pressure resistance standards indicated in the parentheses. | |||
| 1250 | 80 | 31.5-4 | 230 | |||||||||||||
| 1600 2000 | 100 | 40-2 | 3150 | 260 | ||||||||||||
| 2500 | 125 | 50-2 | ||||||||||||||
| 3150 | 125 | 50-3 | 280 | |||||||||||||
| (145) | 145 | 1250 | 80 | 31.5-4 | 275 | 315 | 650 | 750 | 6±1 | Height: 500, Width: 170 | 2400 | 3800 | 300 | Can be used for a system at an altitude of 4000 meters with a voltage of approximately 110KV. | ||
| 1600 2000 | 100 | 40-2 | Height: 1250, Width: 420 | 320 | ||||||||||||
| 380 | ||||||||||||||||
| 3150 | 125 | 50-3 | ||||||||||||||
| 220(245) | 252 | 1250 | 100 | 40-3 | 450 | 530 | 1050 | 1200 | 6±1 | 1000 | 0.5 | 3740 | 5500 6300 | 630-710 | ||
| 1600 2000 2500 | 125 | 50-3 | 650-750 | |||||||||||||
| 3150 | 690-780 | |||||||||||||||


Testimonials
A Disconnector Switch is used to isolate the electrical power modules of a power system among themselves. It is the custom to operate it after the circuit breaker has interrupted the current, defining a separation point for maintenance, inspection, replacement of material, or planned work in the system.
Standard designs comprise the center-break, double-break and pantograph type disconnectors, which can be executed with various mounting and operating solutions. Selection is based on voltage level, electrical clearance, conductor configuration, available space and substation design.
Rating voltage, rated current, degree of insulation, short-time current withstand, installation method, phase distance, type of operating mechanism, earthing method, and dimension should be considered when selecting a disconnector. The disconnector should be also be matched to the circuit breaker and switchgear.
A Circuit Breaker operates to open a circuit automatically and quench the arc presently established while interrupting to currents such as load, fault and short circuit currents in normal and abnormal conditions in medium voltage (MV) or high voltage (HV) within a single break using one of the arc-quenching mediums (vacuum or SF6). A disconnector switch (isolator) cannot extinguish an arc and should only be used when there is no load on it. The main purpose of the tool is to establish a visible, physical air-insulation barrier that provides certainty that technicians working on downstream equipment are safe.
A Load Break Switch is provided with a quite simple type of arc-chutes or interrupters which allows to safely make and break under normal continuous load currents, but it is not possible to interrupt short-circuit fault currents. A Disconnector Switch is not designed to interrupt load currents; rather, it serves as an isolation device that provides additional assurance of physical disconnection after the breaker has broken the current, and is connected in series with a circuit breaker.
Indoor Disconnector Switches are used where there are indoor switchgear and electrical rooms and size and coordination of equipment are taking value. For outdoor models, the open-air installation demands that more attention is paid to the weather at the site, contamination, corrosion, and other environmental factors.
Yes. The Disconnector Switches can be electric or motorized with a various options of control devices and are used especially in substations where centralized control or automation is needed.
Yes. Disconnectors are usually a component of medium voltage and high voltage switchgear. Their size, electrical ratings, operating mechanism and interlocking scheme must be adapted to the switchgear design for a proper operation.
The delivery date is determined by the quantity. Usually, the order takes 2 to 3 weeks. For large orders, we can negotiate with you.
Related Product
The HV porcelain column type SF6 circuit breaker is an outdoor circuit breaker that utilizes a porcelain housing for external insulation and SF6 gas as the medium for arc quenching and insulation.
HV Integrated Type(Split-Type) SF6 Circuit BreakerThe HV Integrated (split-type) SF6 circuit breaker features an SF6 high-voltage circuit breaker in which the pole unit and the operating mechanism are integrated into a single assembly.
The ZW8-12F outdoor high-voltage intelligent vacuum circuit breaker is an intelligent circuit breaker designed for 12kV pole-mounted distribution networks, featuring an integrated controller.
ZW20-12 Series Outdoor High Voltage Vacuum Circuit BreakerThe ZW20-12 outdoor high-voltage vacuum circuit breaker is a high-performance pole-mounted circuit breaker that utilizes SF6 gas for insulation and a vacuum interrupter for arc extinction.
A high-voltage porcelain surge arrester is a high-voltage overvoltage protection device that utilizes zinc oxide valve elements as its core components and a porcelain housing as its external insulation.