Why Choose Lugao High Voltage Switchgear
- More than two decades long experience in manufacturing high-voltage electrical equipment.
- The manufacturing workshop is more than 10,000 square meters with advanced production equipment.
- Hundreds of seasoned employees with years of expertise in the electrical industry.
- The electrical equipment is exported to over 50 countries worldwide and operates reliably.
- Lugao has obtained ISO, CE, and IEC certifications and secured the relevant test reports.
- Lugao provides OEM and ODM technical support for various projects.
Source Factory for High Accuracy Current Transformer
Lugao possesses over twenty years of extensive experience in electrical equipment manufacturing, with current transformers serving as a core product. All current transformers are manufactured in accordance with IEC standards and hold relevant certifications.
Current transformers (CTs) must not only step down the primary current but also provide usable secondary signals for protective relays. When designing its current transformers, Lugao carefully considers key parameters—such as rated primary current, transformation ratio, accuracy class, rated burden, insulation level, and type (protection or metering)—to ensure accurate readings and reliable protection.
Please provide us with your current transformer ratio and system requirements so that we can offer professional recommendations for selecting the right current transformers for your project.
Customized Current Transformer Tailored to Your Need
Lugao offers current transformers in various configurations for precision current measurement and protection, such as outdoor current transformers, oil-immersed current transformers, and SF6 current transformers.

The LVQB(T) series current transformer utilizes SF6 gas as the insulating medium and features an inverted structure

LZZBJ-type dry-type epoxy resin insulated current transformer features epoxy resin insulation with an external silicone rubber layer, providing a long creepage distance.

LB-type current transformer features a steel tank filled with cooling and insulating oil, with heat dissipated through natural convective circulation.

The LVB-type current transformer is suitable for use in 50 Hz, 220 kV power systems, where it performs current monitoring and relay protection functions.

LXK-type zero-sequence current transformer is suitable for a wide range of cable sizes and offers high flexibility.
Why You Need Lugao Current Transformer
Lugao’s current transformers use high-permeability core material, which in conjunction with the APG void-free epoxy casting method, and the use of heavy primary copper winding helps to prevent ratio drift, internal partial discharge, and thermal damage due to short circuit.

The ratio of primary to secondary is chosen based on the system current and is designed to produce measurement signals appropriate for the connected meters and protection devices.

Secondary windings can be configured as needed for the metering, protection and control circuits and are compatible with various substation designs.

For oil-immersed designs, the insulating oil provides both electrical insulation and heat transfer, and is used to control the thermal conditions during continuous operation.

Metering and protection accuracy classes are defined as per project requirement, which can be selected as per the requirement, which helps the customer to avoid using a CT with measurement or relay protection application.
Precise CT Selection for Different Measurement Requirements
Current Transformer selection should be based on the actual primary current, secondary output, accuracy class, burden, and measurement application of the system. Lugao provides various Current Transformer configurations for metering and protection applications, guiding engineers to avoid incorrect ratios or incompatible accuracy classes that result in measurement deviation or protection failures. As a result, Current Transformer selection is much more representative of the specific requirements of each power system.


Dedicated Protection Performance for Fault Current Detection
The Current Transformer needs to continue to provide useful current information to the protection relays during the short-circuit or overload condition. The Lugao CTs can also be designed with protection cores and accuracy classes suitable for fault detection and relay work. The design concentrates have been established not just to normal-load meter, but to reliable signal communication in an abnormal current flow in the power system.
Current Transformer Technical Resources
Get access to our comprehensive product catalog to learn about complete technical specifications, design, and configuration options.
Download our certified international certificates and type test reports to inspect our factory.
Watch our factory online and explore the manufacturing process of electrical equipment.
Your Trusted Current Transformer Manufacturer


Lugao controls the Current Transformer manufacturing process from the stage of winding and insulation assembly to the final electrical testing, which allows for the verification of important parameters before shipping. This production and testing control the transformation ratio, insulation performance, secondary circuit condition, and product consistency, and it gives a high chance of avoiding Current Transformer-related problems being found only after the product has been installed and commissioned.
Applications of Current Transformer

Current Transformers are used on incoming and outgoing circuits, transformers and busbar sections to provide scaled current signals for metering and protection equipment.

The CT fulfills the dual functions of providing insulation and thermal withstand capability for the high-voltage main circuit while also serving as a support for the contact box, making it suitable for compact switchgear interiors.

Current Transformers are used in large industrial applications to measure the current of a feeder or transformer without having to route the high primary currents directly to meters or relays.

Current transformers (CTs) are used in generator and transformer circuits to provide signals for measurement and protection, and to respond to abnormal operating conditions.

The outdoor epoxy resin current transformer features a high protection rating and is designed for use with automatic reclosers.

High-voltage current transformers supply current information to protective relays, helping the system identify abnormal current conditions.
- LB6-110 Current Transformer Drawing
- LB7-220 Current Transformer Drawing
- TYD110 Current Transformer Drawing
- TYD115 Current Transformer Drawing




Testimonial
A Current Transformer mainly serves the high primary current into much smaller secondary current for meters, protection relay and monitoring instrument that considered to be safe. It enables the measurement and protection of high-current circuits without the need to connect those circuits directly to sensitive secondary equipment.
The accuracy class exists in order to indicate the allowed measurement or total error in defined conditions. Typical metering classes are 0.1, 0.2, 0.5 and 1 and protection CTs use classes like 5P, 10P. The relevant class is application specific.
1A and 5A are standard secondary ratings for CTs. A 1A secondary can minimize losses for long secondary wiring runs, 5A is still widely used in existing protection and metering systems.
The CT ratio shall be chosen considering the traffic under maximum primary current, operating conditions of the system, the connected load or secondary burden and the requirements of meter or protection device.
An oil-immersed current transformer utilizes insulating oil as part of its insulation and heat dissipation system. It is commonly used in high-voltage outdoor applications requiring continuous operation.
Testing may include turns ratio verification, polarity checks, winding resistance measurement, insulation testing, accuracy verification, and other tests required by applicable standards.
Metering current transformers are designed to maintain their accuracy primarily for measurement purposes within their normal range of operation, while protection current transformers are intended to provide a signal that can be used by protective relays to operate during a fault.
Yes, Lugao’s engineers can customize specifications—such as the current ratio, terminal configuration, and mounting brackets—to suit the specific requirements of your project.
Related Product
JDQXF SF6 Gas Insulated Voltage TransformerThe JDQXF SF6 gas-insulated voltage transformer is a piece of high-voltage outdoor metering equipment that utilizes SF6 gas as an insulating medium.
JDZX9 Outdoor Single-Phase Voltage TransformerThe JDZX9 outdoor single-phase voltage transformer is an outdoor metering device featuring a fully enclosed, dry-type epoxy resin cast design.
The JDZ cast-resin voltage transformer is an indoor voltage-transforming device that utilizes fully enclosed epoxy resin casting for insulation.
The SZ series on-load tap-changing transformer is a type of power transformer capable of adjusting its tap changer—either automatically or manually—while under load, in order to regulate voltage levels.
A dry type cast resin transformer is a piece of transformer equipment in which the windings are vacuum-encapsulated with epoxy resin.
















