x
Send Your Inquiry Today
Quick Quote
Outdoor Disconnector Switch Manufacturer in China

Outdoor Disconnector Switch Manufacturer in China

Lugao’s outdoor HV disconnector switches are designed for high-voltage circuits in outdoor power distribution systems and operate reliably under extreme outdoor environmental conditions.

  • Facilitates safe isolation and allows for intuitive visual verification.
  • Resistant to harsh weather and corrosion from the natural environment.
  • No mechanical jamming or rusting occurs during long-term switching operations.
  • Customized Solutions for Different Substation Applications
  • Why Choose Lugao Outdoor Disconnector Switch
  • Why Choose Lugao Outdoor Disconnector Switch
  • Why Choose Lugao Outdoor Disconnector Switch
  • Why Choose Lugao Outdoor Disconnector Switch
  • Why Choose Lugao Outdoor Disconnector Switch
  • Why Choose Lugao Outdoor Disconnector Switch

Why Choose Lugao Outdoor Disconnector Switch

  • Over twenty years of experience in manufacturing high-voltage electrical equipment.
  • Production workshop exceeding 10,000 square meters; ample factory space.
  • Hundreds of highly experienced employees deeply rooted in the electrical industry.
  • Successfully exported to over 50 countries worldwide and highly acclaimed.
  • We have been awarded with ISO9001 certificate and our products are certificated by CE, IEC and got relative test reports.
  • Providing OEM and ODM customization services.

Source Factory for Outdoor HV Disconnect Switch

With more than 20 years of professional experience in manufacturing High Voltage electrical Disconnector Switch, Lugao has delivered and supplied thousands of outdoor units to power transmission grids, high voltage substations, and heavy industrial applications in over 50 countries in the world.

Designed for outdoor high voltage applications, Lugao’s outdoor disconnector switches(Isolator switch) are focused on safe electrical isolation and superior long term weatherability. Their solid mechanical design, high quality contacts and sealing solutions prevent oxidation of contacts, jamming of mechanism and these switches can even be used in extreme temperatures.

For any inquiries please contact Lugao; we will offer a full high voltage electrical disconnector switch solution and a factory direct quotation within 24 hours.

Customized High-Voltage Outdoor Disconnector Switches

Lugao Power production outdoor disconnect switches for rural distribution feeders 12 kV 36 kV, to major public transmission substations, 110 kV 252 kv.

Gw5 Outdoor HV Disconnector Switch
Gw5 Outdoor HV Disconnector Switch

The GW5 series V-type center-break disconnect switches (33kV–132kV) are equipped with manual and motor-operated mechanisms and are suitable for long-term outdoor use.

Gw4 Outdoor HV Disconnector Switch
Gw4 Outdoor HV Disconnector Switch

GW4 series is a double-column, horizontally rotating outdoor disconnect switch featuring a visible break; it can be equipped with either a manual or an electric operating mechanism.

RH-B Series HV Disconnector Switch
RH-B Series HV Disconnector Switch

RH-B series three-phase outdoor disconnect switch is designed for applications requiring three-phase load switching and is available with either porcelain or silicone rubber insulation.

GW9 MV Single-Pole Disconnector Switch
GW9 MV Single-Pole Disconnector Switch

The GW9 series is suitable for outdoor AC no-load isolation in 50/60 Hz, 6.6–24 kV systems, with rated currents ranging from 200 A to 1250 A.

Why You Need Lugao Outdoor Disconnector Switch

Lugao outdoor disconnector switches service the safe and visual isolation of high voltage circuits in outdoor power distribution equipment applications; with metal components that resist corrosion and manual or electric operator mechanics, they provide dependable performance for extended service.

Visible Isolation Design
Visible Isolation Design

Allows a clear separation in the physical plane, making it possible for the operator to visually verify circuit isolation during work on the system or while performing inspections.

Excellent Outdoor Weather Resistance
Excellent Outdoor Weather Resistance

Constructed with durable materials and a protective design, it withstands rain, dust, temperature fluctuations, and harsh outdoor working environments.

Exceptional Mechanical Durability
Exceptional Mechanical Durability

The integrated mechanical interlocking device prevents the disconnector from being opened under load and support frequent switching operations

Pre-Calibrated Three-Phase Synchronization
Pre-Calibrated Three-Phase Synchronization

Three-phase mechanical linkage mechanism is calibrat ed in the factory on the precision alignment platform, which avoid the phase sequence misalignment error during the field installation.

Maintain Isolation Performance During Long-Term Operation

The contact resistance and erosion may be increased due to long-term outdoor rain and oxidation for outdoor disconnector switches(Isolator switch) used in power systems. Every disconnector switch is uniquely designed to provide optimal current paths and robust mechanisms, and incorporates silver plated copper contacts to maintain low resistance conductivity over time and reduce maintenance.

Maintain Isolation Performance During Long-Term Operation
Customized Disconnector Solutions for Complex Requirements

Customized Disconnector Solutions for Complex Requirements

Voltage levels, mounting styles and modes of operation vary between substations and power systems. Lugao offers tailor-made outdoor disconnector solutions to project conditions – from configuration and type selection to technical specifications. These products are available in non-grounding type, single grounding type, and double grounding type switches with manual, motorized or automatic operating mechanisms, to eliminate compatibility issues for customers during installation.

Lugao's Electrical Equipment Technology Resources

Catalog Download
Catalog Download

Get access to our comprehensive product catalog to learn about complete technical specifications, design, and configuration options.

Qualification Download
Qualification Download

Download our certified international certificates and type test reports to inspect our factory.

Video
Video

Watch our factory online and explore the manufacturing process of electrical equipment.

Your Trusted Outdoor Disconnector Switch Manufacturer

Your Trusted Outdoor Disconnector Switch Manufacturer
Your Trusted Outdoor Disconnector Switch Manufacturer

In order to avoid problems during the installation of the high voltage outdoor disconnect switches that we provide, Lugao performs full factory tests on every unit—mechanical operation, insulation test, electrical performance and contact resistance tests. This takes all the nasty fine tuning out of the field and guarantees you buttery smooth effortless operation (manual or electric) and long lasting dependable performance.

Applications of Outdoor Disconnector Switch

Rural Pole-Mounted Distribution Network
Rural Pole-Mounted Distribution Network

Outdoor disconnect switches(Isolator switch) mounted on poles should be lightweight and highly weather-resistant. Additionally, they should be able to be operated with an insulated operating rod by maintenance staff from the ground.

Wind Substation Plants
Wind Substation Plants

Outdoor disconnect switches feature an exceptionally long mechanical operating life, meeting the requirements of wind power plants for frequent switching operations.

Power Transmission and Transformation Substation
Power Transmission and Transformation Substation

Outdoor disconnector switches have visible breaks, serving as a physical safety barrier to isolate the busbar from the line during maintenance.

Industrial Power Grid
Industrial Power Grid

Employed in industrial substations to securely isolate transformers, switchgear and electrical apparatus for the purpose of operating and servicing.

High-Altitude Area Power Grid
High-Altitude Area Power Grid

The specially designed outdoor disconnector switch features a high-torque, ice-breaking linkage mechanism and specialized contacts, resolving difficulties associated with closing the switch.

Coastal Power Grid
Coastal Power Grid

Outdoor disconnectors utilizing composite or porcelain insulators with long creepage distances can prevent flashover and breakdown caused by frequent salt spray in coastal areas.

Get an Instant Quote Now

Quick Quote

One-Stop Wholesale of Outdoor Disconnector Switches

One-Stop Wholesale of Outdoor Disconnector Switches

Simplify your bulk disconnector purchase with factory-direct pricing, quick assembly, and proven dependability.

Rated Voltage

 

Highest Voltage

 

Rated Current

 

Dynamic Stability Peak Current (✓)

 

Thermal Stability Effective Current (✓)

 

1-Min Power Frequency Withstand Voltage (RMS)

 

Lightning Impulse Withstand Voltage (Peak)

 

Opening/Closing Time

 

Terminal Rated Force

 

Breaking Current Capacity

 

Creepage Distance

 

Pole Weight

 

Remarks

 

To Earth

 

Across Break

 

To Earth

 

Across Break

 

KVKVAKAKA-5KVKVSNAMMKg
Standard

 

Anti-Pollution

 

35(40.5)40.56305020-495118185215500625875120
10008031.5-4145
160010040-21225170
2000
66(72.5)72.56305020-414016032537550011001600180
12508031.5-4200
160010040-21813225
2000
250012550-22205230
315012550-3240
110(126)1266305020-4230
(185)
265
(450)
550
(450)
630
(520)
75018702750200Can be used at 2500m altitude according to international withstand voltage standards in vibration type

 

12508031.5-4230
160010040-23150260
2000
250012550-2
315012550-3280
(145)14512508031.5-42753156507506±1L 500 T 170

 

24003800300Can be used for approx. 110kV system at 4000m altitude

 

160010040-2320
2000380
315012550-3
220(245)252125010040-3450530105012006±110000.537405500630-710
160012550-3650-750
2000690-780
2500
3150
ItemGW9-12
Rated Voltage12 kV
Rated Frequency50/60 Hz
Rated Current200 / 400 / 630 / 800 / 1000 / 1250 A
Rated Short-Time Withstand Current6.3 / 12.5 / 20 / 25 / 25 / 31.5 kA,4 s
Rated Peak Withstand Current16 / 31.5 / 50 / 63 / 63 / 80 kA
Power-Frequency Withstand Voltage – To Ground40–42 kV / 1 min
Power-Frequency Withstand Voltage – Across Open Contacts47–48 kV / 1 min
Lightning Impulse Withstand Voltage – To Ground75 kV
Lightning Impulse Withstand Voltage – Across Open Contacts85 kV
Operating StructureSingle-Break Vertical Opening Type
Operating MechanismManual Operating Mechanism
Maximum Altitude≤1,000 m
Applicable StandardIEC 62271-102 / GB 1985
Insulation MediumAir Insulation
Number of Poles3 Poles
1Rated Voltage (kV)40.5126
21min power frequency withstand voltage (Effective value) kVTo Ground95230
Between Fracture115245
3Lightning Impulse withstand voltage (Peak value) kVTo Ground185550
Between Fracture215630
4Mechanical life (Times)2000
5Rated Current (A)63012501600
6Rated short time withstand Current (kA)2031.540
7Rated withstand current (Peak value) kA5080100
8Rated connect machine load (N)Horizontal vertical7501000
Horizontal transverse500750
Vertical force7501000
9Creepage distance (mm)1013-22561813-2250
10Manual operating MechanismModelCS17,CS17G
Control loop voltage (V)AC220,DC110,DC220
11Motor operating mechanismModelCJ6
Motor voltage (V)AC220,AC380,DC220
Control loop voltage(V)AC220,AC380,DC220
Switching time (s)6±1

Testimonials

  • Contact erosion in traditional disconnect switches frequently caused emergency line outages during periods of high summer loads. We upgraded to Lugao outdoor circuit breaker switches; thanks to their optimized contact design and superior performance, operating temperatures remain normal even under continuous full-load conditions.

    Nabil El-Masry
    Nabil El-Masry
    Power Project Manager
  • Operational safety is the number one priority in the work we do in substations. We chose Lugao’s outdoor motorized disconnect switches for their dependable mechanical and electrical interlock features. It can only be closed with the main blade de-energized making our dispatch team absolutely safe during maintenance on the grid.

    Chidiebere Okeke
    Chidiebere Okeke
    Substation Maintenance Lead
  • Salt spray at one of our coastal substations caused persistent flashovers on the disconnect switch insulators. We installed outdoor disconnect switches manufactured by Lugao, featuring high-creepage silicone rubber insulators and hot-dip galvanized steel frames. After long-term operation, no flashovers have occurred, and the frames show no signs of rust.

    Thabo Mokoena
    Thabo Mokoena
    EPC Project Manager
What is an Outdoor Disconnector Switch used for?

An Outdoor Disconnector Switch is primarily employed for high voltage power system electrical isolation for a portion of power system during maintenance, inspection or switching activity. Its position when open is visible, enabling operators to verify that the equipment has been disconnected from the energized circuit prior to starting work.

What is the main difference between an Outdoor Disconnector Switch and a Load Break Switch (LBS)?

An Outdoor Disconnector Switch (Isolator) is for safe disconnection isolation only, it does not have any arc extinguishing means, and it should be operated in no load condition to open a visible air contact gap for safe working. A Load Break Switch (LBS) has arc-chutes or vacuum interrupters that can interrupt the load current in an active condition.Disconnectors are usually mounted in series with circuit breakers to provide fail-safe physical isolation after the breaker has cleared the fault current.

What voltage levels are available for Outdoor Disconnector Switches?

Outdoor disconnector switches are suitable for various medium and high voltage applications. Commonly used rated voltages include 11kV, 33kV, 66kV, 110kV, 132kV and higher voltage levels. The specific rated voltage should be selected based on the system voltage and insulation requirements.

What is the difference between a manual and motorized disconnector?

A manual disconnector works locally with the mechanical drive system, and the motorized disconnector can be driven electrically or remotely. Motorized operation is especially advantageous for substations whose switching operations are carried out from a control room.

What factors should be considered when selecting an outdoor disconnect switch?

Main selection criteria: Rated voltage, rated current, insulation class, short-time withstand current, installation type, operating mechanism, creepage distance, environmental conditions and required earthing configuration. Also should be taken into account the available space and the substation busbar layout.

What maintenance does an Outdoor Disconnector Switch require?

Ordinary cleaning and adjusting consist in observing the state of the contacts, of the insulation surfaces, of the parts constituting the mobile and fixed contacts, of the operating organs, of the fasteners and of the grounding connections and of the lubrication, if established. The frequency of inspection should take into account the environment, the number of operations, the degree of contamination, and the specific equipment instructions.

What tests should be performed before an Outdoor Disconnector Switch is delivered?

Mechanical operation inspection, insulation-related tests, contact resistance measurement, dimensional inspection, and verification of operating mechanisms.

Where are Outdoor Disconnector Switches commonly installed?

Outdoor disconnector switches are typically installed in power transmission and distribution substations, outdoor switch stations, renewable energy power plants, industrial substations, and high-voltage network connection points.

Related Product

  • GN30-12 Indoor HV Disconnector Switch

    The GN30-12 indoor high-voltage disconnector switch is primarily used in switchgear to isolate the power supply and provide a safe, visible disconnection point.

  • GN27-40.5 Indoor HV Disconnector Switch
    GN27-40.5 Indoor HV Disconnector Switch

    The GN27-40.5 indoor high-voltage disconnector switch is used to open and close circuits under no-load conditions and to isolate power sources.

  • HXGN□-12 Fixed Enclosed Switchgear

    HXGN□-12 fixed enclosed switchgear features a compact design, safety and reliability, and a simple structure.

  • XGN66-12 Fixed Closed Switchgear
    XGN66-12 Fixed Closed Switchgear

    The XGN66-12 fixed enclosed switchgear features a compact design, comprehensive “five-prevention” interlocking, and ease of maintenance.

  • Armored Withdrawable Metal Clad Switchgear

    Armored, withdrawable, metal-clad switchgear is a type of medium- or high-voltage power distribution equipment in which the interior is divided into multiple independent compartments by all-metal partitions.

WeChat
WeChat QR
WhatsApp
WhatsApp QR
Call Now
Email Now
Scroll to Top