Why Choose Lugao Potential Transformer
- Possesses over twenty years of professional engineering and production experience.
- Operates a dedicated high-voltage manufacturing plant covering an area of over 10,000 square meters.
- Boasts a workforce of over a hundred highly skilled employees, including senior electrical engineers and an R&D team.
- Its products have been successfully exported to over 50 countries worldwide and have received high acclaim.
- Equipped with production lines certified to ISO 9001, ISO 14001, and ISO 45001 standards.
- Supports OEM/ODM customization services tailored to specific load requirements and physical installation dimensions.
Potential Transformer for Precise Voltage Measurement
Lugao Potential transformers (PT) are designed for power generation, transmission, distribution, and industrial electrical systems. Drawing on years of experience in electrical equipment manufacturing, Lugao is committed to delivering products of exceptional quality and reliability.
These potential transformers step down high-side voltage to standard secondary voltage levels while meeting the accuracy requirements of connected metering instruments, relays, and monitoring systems. Key specifications—such as transformation ratios, accuracy classes, insulation levels, and specific operating conditions—can be customized to meet your needs.
Please provide Lugao with details regarding your system voltage and application requirements, and we will recommend the most suitable potential transformer solution for you.
Customized Potential Transformers for Your Project
Potential transformers (PTs)—also known as voltage transformers (VTs)—from Lugao feature high dielectric strength and a compact design; various voltage ratings and configurations are available to meet your project requirements.

The JDQXF type voltage transformer is a single-phase, outdoor type, and is used for rated voltages of 35 kV, 66 kV, 110 kV, and 220 kV.

The JDC5-220 voltage transformer is a fully sealed, cascade-type unit featuring oil-paper insulation; it is available in single-phase versions with either three or four windings.

The JDCF-66 voltage transformer features a single-phase, four-winding, cascade-type insulation structure and is suitable for use in 66 kV systems.

The JDJ(J) type voltage transformer is a single-phase, oil-immersed unit suitable for use in systems rated at 35 kV and below.

The JLS-10/35 outdoor oil-immersed high-voltage instrument transformer—also known as a metering unit—is designed for electricity metering in 10 kV or 35 kV power grids.

The JDZ-type voltage transformer is a single-phase, two-wire indoor unit featuring epoxy resin cast insulation, suitable for use in power systems rated at 10 kV (or 6 kV) and below.

The JDZX9-35 is a single-phase, epoxy resin-cast voltage transformer designed for outdoor medium- and high-voltage systems (up to 35 kV).
Why You Need Lugao Power Potential Transformer
Lugao potential/voltage transformers (PT/VT) meet stringent international standards, their accuracy and reliability permit safe and dependable operation both indoors and outdoors with the highest requirements in medium and high voltage applications.

The primary-to-secondary voltage is established as per-system requirements, resulting in meters, relays, and monitoring equipment seeing the proper voltage signal.

Various accuracy classes can be chosen depending on metering or protection requirements to ensure proper measurement performance under defined operating conditions.

Different construction and mounting configurations can be selected according to switchgear, substation, indoor, outdoor, and other installation requirements.

The Potential Transformers (PT) can be designed with Lord windings for metering, protection, monitoring or any other voltage measurement application.
Lugao Offers a Variety of PT/VT Solutions
The importance of the PT insulation system increases with system voltage. Lugao Potential Transformers are tailored for the rated voltage, insulation class, operating environment and the structure. Oil-filled types can accommodate the most severe outdoor high voltage applications, whereas dry-type ones allow for oil-free application indoors and in electrical apparatus rooms.


Direct Factory Engineering & Fast-Track OEM Customization
Eliminate switchgear installation delays with tailored Potential Transformer (PT) designs. Our engineering team can transform your single-line diagram (SLD) into fully validated CAD drawings within 24 hours. Whether the requirement involves unique primary terminal spacing, specific secondary voltage taps, or other custom specifications, Lugao delivers completed orders in approximately two weeks.
Potential/Voltage Transformer Technical Resources
Get access to our comprehensive product catalog to learn about complete technical specifications, design, and configuration options.
Download our certified international certificates and type test reports to inspect our factory.
Watch our factory online and explore the manufacturing process of electrical equipment.
Your Trusted HV/MV Potential Transformer manufacturer


Each potential/voltage transformer of LUGAO will be testedd strictly the dielectric performance, because a minor phase error can distort power factor measurements of the whole feeder circuit. In order to ensure the accuracy of measurements, each unit is tested under normal conditions shielded in a high-voltage laboratory. Each one of our products is put through a series of tests that include power-frequency withstand voltage, lightning impulse withstand, and partial discharge testing. This is why we test every VT before shipping, so you can be confident that it will work immediately upon installation, allowing for a smooth energization and continued grid protection.
PT Applications Across Power Systems

Potential transformers are typically installed inside high-voltage switchgear to provide secondary voltage signals to other components.

Uses an outdoor waterproof-type PT featuring a structure with extended creepage distance, providing resistance to UV radiation and the elements.

Potential Transformers provide voltage signals from incoming and outgoing circuits to meters, protection relays, and monitoring systems

Industrial facilities utilize potential transformers to obtain voltage signals for use by switchgear for metering, power monitoring, and protective relays.

Potential transformers provide voltage feedback at renewable energy collection points and grid connection points.

PTs provide generator and busbar voltage signals for electrical measurement, protection, synchronization, and operational control within the power plant.
- JDQXF Technical Specifications
- JLS-6 Technical Specifications
- JDCF-66 Technical Specifications
| PRODUCT MODEL | JDQX-5W2 | JDQXF-66W2 | JDQXF-110W2 | JDQXF-220W2 |
| Rated primary voltage (kV) | 35/√3 | 66/√3 | 110√3 | 220/V3 |
| Rated frequency (Hz) | 50 | 50 | 50 | 50 |
| Maximum operating voltage (kV) | 40.5 | 72.5 | 126 | 252 |
| Rated secondary voltage (V) | 100/√3 | 100/√3 | 100/√3 | 100/√3 |
| Rated voltage of residual voltage winding (V) | 100/3 | 100/3 | 100 | 100 |
| Accuracy level (combination) | 0.2/3P | 0.2/0.5/3P | 0.2/0.5/3P | 0.2/0.5/3P |
| Rated output (corresponding) (VA) | 50/100 | 100/100/100 | 150/150/300 | 100/150/300 |
| Rated voltage factor/time | 1.9/8h | 1.9/8h | 1.5/30S | 1.5/30S |
| Primary winding grounding terminal withstand voltage (kV) | 5 | 5 | 5 | 5 |
| Induction withstand voltage of primary winding (KV) | 95 | 160 | 230 | 460 |
| Lightning full wave impulse gate voltage (peak kV) | 200 | 350 | 480 | 950 |
| Lightning cut-off impulse withstand voltage (peak kV) | 220 | 360 | 530 | 1050 |
| Zero meter withstand voltage (kV) | 30.4 | 55 | 95 | 190 |
| Working air pressure/supplementary air pressure (MPa) | 0.4/0.35 | 0.4/0.35 | 0.4/0.35 | 0.4/0.35 |
| Partial discharge level (pC) | ≤5 | ≤5 | ≤5 | ≤5 |
| Rated thermal limit output (VA) | 500 | 1000 | 2000 | 1500 |
| Annual gas leakage rate | ≤0.5% | ≤0.5% | ≤0.5% | ≤0.5% |
| model | Rated primary voltage (kV) | Measure the secondary winding | Protecting the secondary winding | residual voltag winding | Secondary winding limit output (VA) | rated insulation level | Creepage distance cm/kV | Oil weight/ total weight kg | ||||||
| Rated voltage (kV) | accuracy class | Rated output (VA) | Rated voltage (kV) | accuracy class | Rated output (VA) | Rated voltage (kV) | accuracy class | Rated output (VA) | ||||||
| JDCF5-66W1 | 66/ √ 3 | 0.1/ √ 3 | 0.2 | 50 | 0.1/ √ 3 | 3P | 400 | 0.1/3 | 3P | 100 | 2000 | 72.5/ 140/ 325 | 2.5 | 90/530 |
| model | Rated primary voltage (kV) | Measure the secondary winding | Protecting the secondary winding | residual voltag winding | Secondary winding limit output (VA) | rated insulation level | Creepage distance cm/kV | Oil weight/ total weight kg | ||||||
| Rated voltage (kV) | accuracy class | Rated output (VA) | Rated voltage (kV) | accuracy class | Rated output (VA) | Rated voltage (kV) | accuracy class | Rated output (VA) | ||||||
| JDCF5-66W1 | 66/ √ 3 | 0.1/ √ 3 | 0.2 | 50 | 0.1/ √ 3 | 3P | 400 | 0.1/3 | 3P | 100 | 2000 | 72.5/ 140/ 325 | 2.5 | 90/530 |
Testimonial
A Potential Transformer, commonly called PT or Voltage Transformer (VT), reduces high primary voltage to a lower standardized secondary voltage that can be safely used by meters, protection relays, monitoring devices, and control systems. It provides an electrically isolated voltage signal while maintaining a defined transformation ratio and accuracy.
A Potential Transformer (PT) is used to transform voltage and a Current Transformer (CT) is used to transform current. PTs are used to obtain a secondary voltage signal that is proportional to the primary voltage for voltage measurement and protection, and CTs are used to obtain a secondary current signal proportional to the primary current. They are usually installed together in substations and switchgear to supply the electrical information needed by metering and protection equipment.
A Potential Transformer (PT) provides a stepped-down, electrically isolated voltage signal that reflects the voltage of the primary system. Protective relays, energy meters, monitoring equipment, synchronization systems, and control devices can utilize this signal without requiring direct connection to the high-voltage circuit.
The primary voltage should be the same as the system voltage and the secondary voltage should be the voltage required by the load. The choice should also take into account the accuracy class, burden, insulation class, frequency, application technique, and if the secondary circuit will be used for metering, protection, or both.
The accuracy class defines the maximum difference between the secondary voltage and the ideal secondary voltage, given specific operating conditions. For metering applications, the voltage measurement accuracy is typically of higher importance, while for protection applications, the characteristics are chosen to be compatible with the operation of the protection system.
Oil-immersed Potential transformers (PTs) utilize insulating oil as part of their internal insulation system and rely on the oil for heat dissipation. This design is typically employed in outdoor and/or high-voltage applications.
Dry type PTs use solid insulation instead of insulating oil. It is widely used in indoor switchgear, substations, industrial plants and in applications where oil free electrical equipment is required.
Please provide the system voltage, primary and secondary voltages, frequency, accuracy class, burden, insulation class, number of secondary windings, mounting method, and operating environment, as well as whether the PT is intended for metering, protection, or both.
Related Product
Zero-Sequence Current TransformerA zero-sequence current transformer is a type of protective transformer specifically designed to detect system ground faults and leakage currents.
An SF6 gas-insulated current transformer is a type of high-voltage current measurement device that utilizes SF6 gas as an insulating and arc-extinguishing medium.
Oil-Immersed Type Current TransformerAn oil-immersed type current transformer is a high-voltage current-measuring device that utilizes a composite dielectric consisting of transformer oil and insulating paper.
A polymer-housed surge arrester is an overvoltage protection device that utilizes a silicone rubber composite material for its external insulation.
HY5W Metal Oxide Lightning ArresterThe HY5W metal oxide lightning arrester is a high-voltage overvoltage protection device that utilizes a silicone rubber composite housing and zinc oxide valve elements.