Why Choose Lugao Outdoor Disconnector Switch
- Over twenty years of experience in manufacturing high-voltage electrical equipment.
- Production workshop exceeding 10,000 square meters; ample factory space.
- Hundreds of highly experienced employees deeply rooted in the electrical industry.
- Successfully exported to over 50 countries worldwide and highly acclaimed.
- We have been awarded with ISO9001 certificate and our products are certificated by CE, IEC and got relative test reports.
- Providing OEM and ODM customization services.
Source Factory for Outdoor HV Disconnect Switch
With more than 20 years of professional experience in manufacturing High Voltage electrical Disconnector Switch, Lugao has delivered and supplied thousands of outdoor units to power transmission grids, high voltage substations, and heavy industrial applications in over 50 countries in the world.
Designed for outdoor high voltage applications, Lugao’s outdoor disconnector switches(Isolator switch) are focused on safe electrical isolation and superior long term weatherability. Their solid mechanical design, high quality contacts and sealing solutions prevent oxidation of contacts, jamming of mechanism and these switches can even be used in extreme temperatures.
For any inquiries please contact Lugao; we will offer a full high voltage electrical disconnector switch solution and a factory direct quotation within 24 hours.
Customized High-Voltage Outdoor Disconnector Switches
Lugao Power production outdoor disconnect switches for rural distribution feeders 12 kV 36 kV, to major public transmission substations, 110 kV 252 kv.

GW1 series isolating switch consists of three single-pole isolating switches connected to form an integral unit upon installation, and is equipped with a manual operating mechanism.
Why You Need Lugao Outdoor Disconnector Switch
Lugao outdoor disconnector switches service the safe and visual isolation of high voltage circuits in outdoor power distribution equipment applications; with metal components that resist corrosion and manual or electric operator mechanics, they provide dependable performance for extended service.

Allows a clear separation in the physical plane, making it possible for the operator to visually verify circuit isolation during work on the system or while performing inspections.

Constructed with durable materials and a protective design, it withstands rain, dust, temperature fluctuations, and harsh outdoor working environments.

The integrated mechanical interlocking device prevents the disconnector from being opened under load and support frequent switching operations

Three-phase mechanical linkage mechanism is calibrat ed in the factory on the precision alignment platform, which avoid the phase sequence misalignment error during the field installation.
Maintain Isolation Performance During Long-Term Operation
The contact resistance and erosion may be increased due to long-term outdoor rain and oxidation for outdoor disconnector switches(Isolator switch) used in power systems. Every disconnector switch is uniquely designed to provide optimal current paths and robust mechanisms, and incorporates silver plated copper contacts to maintain low resistance conductivity over time and reduce maintenance.


Customized Disconnector Solutions for Complex Requirements
Voltage levels, mounting styles and modes of operation vary between substations and power systems. Lugao offers tailor-made outdoor disconnector solutions to project conditions – from configuration and type selection to technical specifications. These products are available in non-grounding type, single grounding type, and double grounding type switches with manual, motorized or automatic operating mechanisms, to eliminate compatibility issues for customers during installation.
Lugao's Electrical Equipment Technology Resources
Get access to our comprehensive product catalog to learn about complete technical specifications, design, and configuration options.
Download our certified international certificates and type test reports to inspect our factory.
Watch our factory online and explore the manufacturing process of electrical equipment.
Your Trusted Outdoor Disconnector Switch Manufacturer


In order to avoid problems during the installation of the high voltage outdoor disconnect switches that we provide, Lugao performs full factory tests on every unit—mechanical operation, insulation test, electrical performance and contact resistance tests. This takes all the nasty fine tuning out of the field and guarantees you buttery smooth effortless operation (manual or electric) and long lasting dependable performance.
Applications of Outdoor Disconnector Switch

Outdoor disconnect switches(Isolator switch) mounted on poles should be lightweight and highly weather-resistant. Additionally, they should be able to be operated with an insulated operating rod by maintenance staff from the ground.

Outdoor disconnect switches feature an exceptionally long mechanical operating life, meeting the requirements of wind power plants for frequent switching operations.

Outdoor disconnector switches have visible breaks, serving as a physical safety barrier to isolate the busbar from the line during maintenance.

Employed in industrial substations to securely isolate transformers, switchgear and electrical apparatus for the purpose of operating and servicing.

The specially designed outdoor disconnector switch features a high-torque, ice-breaking linkage mechanism and specialized contacts, resolving difficulties associated with closing the switch.

Outdoor disconnectors utilizing composite or porcelain insulators with long creepage distances can prevent flashover and breakdown caused by frequent salt spray in coastal areas.
- GW4 Technical Specifications
- GW9 Technical Specifications
- GW4 Technical Specifications
| Rated Voltage
| Highest Voltage
| Rated Current
| Dynamic Stability Peak Current (✓)
| Thermal Stability Effective Current (✓)
| 1-Min Power Frequency Withstand Voltage (RMS)
| Lightning Impulse Withstand Voltage (Peak)
| Opening/Closing Time
| Terminal Rated Force
| Breaking Current Capacity
| Creepage Distance
| Pole Weight
| Remarks
| |||
| To Earth
| Across Break
| To Earth
| Across Break
| ||||||||||||
| KV | KV | A | KA | KA-5 | KV | KV | S | N | A | MM | Kg | ||||
| Standard
| Anti-Pollution
| ||||||||||||||
| 35(40.5) | 40.5 | 630 | 50 | 20-4 | 95 | 118 | 185 | 215 | 500 | 625 | 875 | 120 | |||
| 1000 | 80 | 31.5-4 | 145 | ||||||||||||
| 1600 | 100 | 40-2 | 1225 | 170 | |||||||||||
| 2000 | |||||||||||||||
| 66(72.5) | 72.5 | 630 | 50 | 20-4 | 140 | 160 | 325 | 375 | 500 | 1100 | 1600 | 180 | |||
| 1250 | 80 | 31.5-4 | 200 | ||||||||||||
| 1600 | 100 | 40-2 | 1813 | 225 | |||||||||||
| 2000 | |||||||||||||||
| 2500 | 125 | 50-2 | 2205 | 230 | |||||||||||
| 3150 | 125 | 50-3 | 240 | ||||||||||||
| 110(126) | 126 | 630 | 50 | 20-4 | 230 (185) | 265 (450) | 550 (450) | 630 (520) | 750 | 1870 | 2750 | 200 | Can be used at 2500m altitude according to international withstand voltage standards in vibration type
| ||
| 1250 | 80 | 31.5-4 | 230 | ||||||||||||
| 1600 | 100 | 40-2 | 3150 | 260 | |||||||||||
| 2000 | |||||||||||||||
| 2500 | 125 | 50-2 | |||||||||||||
| 3150 | 125 | 50-3 | 280 | ||||||||||||
| (145) | 145 | 1250 | 80 | 31.5-4 | 275 | 315 | 650 | 750 | 6±1 | L 500 T 170
| 2400 | 3800 | 300 | Can be used for approx. 110kV system at 4000m altitude
| |
| 1600 | 100 | 40-2 | 320 | ||||||||||||
| 2000 | 380 | ||||||||||||||
| 3150 | 125 | 50-3 | |||||||||||||
| 220(245) | 252 | 1250 | 100 | 40-3 | 450 | 530 | 1050 | 1200 | 6±1 | 1000 | 0.5 | 3740 | 5500 | 630-710 | |
| 1600 | 125 | 50-3 | 650-750 | ||||||||||||
| 2000 | 690-780 | ||||||||||||||
| 2500 | |||||||||||||||
| 3150 | |||||||||||||||
| Item | GW9-12 |
| Rated Voltage | 12 kV |
| Rated Frequency | 50/60 Hz |
| Rated Current | 200 / 400 / 630 / 800 / 1000 / 1250 A |
| Rated Short-Time Withstand Current | 6.3 / 12.5 / 20 / 25 / 25 / 31.5 kA,4 s |
| Rated Peak Withstand Current | 16 / 31.5 / 50 / 63 / 63 / 80 kA |
| Power-Frequency Withstand Voltage – To Ground | 40–42 kV / 1 min |
| Power-Frequency Withstand Voltage – Across Open Contacts | 47–48 kV / 1 min |
| Lightning Impulse Withstand Voltage – To Ground | 75 kV |
| Lightning Impulse Withstand Voltage – Across Open Contacts | 85 kV |
| Operating Structure | Single-Break Vertical Opening Type |
| Operating Mechanism | Manual Operating Mechanism |
| Maximum Altitude | ≤1,000 m |
| Applicable Standard | IEC 62271-102 / GB 1985 |
| Insulation Medium | Air Insulation |
| Number of Poles | 3 Poles |
| 1 | Rated Voltage (kV) | 40.5 | 126 | ||||
| 2 | 1min power frequency withstand voltage (Effective value) kV | To Ground | 95 | 230 | |||
| Between Fracture | 115 | 245 | |||||
| 3 | Lightning Impulse withstand voltage (Peak value) kV | To Ground | 185 | 550 | |||
| Between Fracture | 215 | 630 | |||||
| 4 | Mechanical life (Times) | 2000 | |||||
| 5 | Rated Current (A) | 630 | 1250 | 1600 | |||
| 6 | Rated short time withstand Current (kA) | 20 | 31.5 | 40 | |||
| 7 | Rated withstand current (Peak value) kA | 50 | 80 | 100 | |||
| 8 | Rated connect machine load (N) | Horizontal vertical | 750 | 1000 | |||
| Horizontal transverse | 500 | 750 | |||||
| Vertical force | 750 | 1000 | |||||
| 9 | Creepage distance (mm) | 1013-2256 | 1813-2250 | ||||
| 10 | Manual operating Mechanism | Model | CS17,CS17G | ||||
| Control loop voltage (V) | AC220,DC110,DC220 | ||||||
| 11 | Motor operating mechanism | Model | CJ6 | ||||
| Motor voltage (V) | AC220,AC380,DC220 | ||||||
| Control loop voltage(V) | AC220,AC380,DC220 | ||||||
| Switching time (s) | 6±1 | ||||||
Testimonials
An Outdoor Disconnector Switch is primarily employed for high voltage power system electrical isolation for a portion of power system during maintenance, inspection or switching activity. Its position when open is visible, enabling operators to verify that the equipment has been disconnected from the energized circuit prior to starting work.
An Outdoor Disconnector Switch (Isolator) is for safe disconnection isolation only, it does not have any arc extinguishing means, and it should be operated in no load condition to open a visible air contact gap for safe working. A Load Break Switch (LBS) has arc-chutes or vacuum interrupters that can interrupt the load current in an active condition.Disconnectors are usually mounted in series with circuit breakers to provide fail-safe physical isolation after the breaker has cleared the fault current.
Outdoor disconnector switches are suitable for various medium and high voltage applications. Commonly used rated voltages include 11kV, 33kV, 66kV, 110kV, 132kV and higher voltage levels. The specific rated voltage should be selected based on the system voltage and insulation requirements.
A manual disconnector works locally with the mechanical drive system, and the motorized disconnector can be driven electrically or remotely. Motorized operation is especially advantageous for substations whose switching operations are carried out from a control room.
Main selection criteria: Rated voltage, rated current, insulation class, short-time withstand current, installation type, operating mechanism, creepage distance, environmental conditions and required earthing configuration. Also should be taken into account the available space and the substation busbar layout.
Ordinary cleaning and adjusting consist in observing the state of the contacts, of the insulation surfaces, of the parts constituting the mobile and fixed contacts, of the operating organs, of the fasteners and of the grounding connections and of the lubrication, if established. The frequency of inspection should take into account the environment, the number of operations, the degree of contamination, and the specific equipment instructions.
Mechanical operation inspection, insulation-related tests, contact resistance measurement, dimensional inspection, and verification of operating mechanisms.
Outdoor disconnector switches are typically installed in power transmission and distribution substations, outdoor switch stations, renewable energy power plants, industrial substations, and high-voltage network connection points.
Related Product
The GN30-12 indoor high-voltage disconnector switch is primarily used in switchgear to isolate the power supply and provide a safe, visible disconnection point.
GN27-40.5 Indoor HV Disconnector SwitchThe GN27-40.5 indoor high-voltage disconnector switch is used to open and close circuits under no-load conditions and to isolate power sources.
HXGN□-12 fixed enclosed switchgear features a compact design, safety and reliability, and a simple structure.
XGN66-12 Fixed Closed SwitchgearThe XGN66-12 fixed enclosed switchgear features a compact design, comprehensive “five-prevention” interlocking, and ease of maintenance.
Armored, withdrawable, metal-clad switchgear is a type of medium- or high-voltage power distribution equipment in which the interior is divided into multiple independent compartments by all-metal partitions.